(ÁÖ)¹ß¸¸ÀνºÆ®·ç¸ÕÆ®¿¡ ¿À½Å °ÍÀ» ȯ¿µÇÕ´Ï´Ù ^^

»ê¾÷¿ë³»½Ã°æ
Straightpoint ÅټǸÞŸ
ALLIED ½ÃÆí°¡°ø±â±â
X-ray&CT °Ë»çÀåÄ¡
Çö¹Ì°æ
°æµµ ½ÃÇè±â
Universal Testing Machine
½ÃÇèÀåºñ/½ÃÆí°¡°ø±â±â
RION ¼ÒÀ½/Áøµ¿°è
Dietert ÁÖ¹°»ç½ÃÇè±â
Àü±â/ÀüÀÚ °èÃø±â
°¡½º/ÃÊÀ½ÆÄ´©¼³ ÃøÁ¤±â
¹°¸®·®/¹°¼º ÃøÁ¤±â
ÅǹеµÃøÁ¤±â/±âŸ ÃøÁ¤±â
OLYMPUS
XENCO
DT
Crane Scale
Tension Scale
Loadcells
±âŸ
½ÃÆíÀý´Ü±â
¸¶¿îÆÃÇÁ·¹½º
Æú¸®½Ì(±×¸®Àεù)
´ëÇüÀý´Ü±â
¼Ò¸ðǰ
CT Inspection
X-ray
¿¡ÄÚÆÁ°æµµ°è
ÃÊÀ½ÆÄ°æµµ°è
·ÎÅ©À£°æµµ°è
ºê¸®³Ú°æµµ°è
ºñÄ¿½º°æµµ°è
¸¶ÀÌÅ©·ÎºñÄ¿½º°æµµ°è
°í¹«/ÇÃ¶ó½ºÆ½°æµµ°è
Ç¥ÁØ½ÃÆí
±âŸ/¾Ç¼¼»ç¸®
¸¸´ÉÀç·á½ÃÇè±â
½ÃÆíÀý´Ü±â
¸¶¿îÆÃÇÁ·¹½º
Æú¸®½Ì¸Ó½Å
³»Èļº½ÃÇè±â
µå¶óÀÌ¿Àºì
¸¶Å·½ÃÇè±â
Schap ½ÃÇè±â
Ãæ°Ý½ÃÇè±â
¿­È­»óÄ«¸Þ¶ó
Àü·ÂǰÁúºÐ¼®±â
Àý¿¬ÀúÇ×ÃøÁ¤±â
Á¢ÁöÀúÇ×ÃøÁ¤±â
Ŭ·¥ÇÁ¸ÞŸ
¸ÖƼ¹ÌÅÍ
ÄÉÀ̺í Å×½ºÆ®±â
´Ù±â´É/ÀÓÇÇ´ø½º/RCDÅ×½ºÅÍ
·¹ÄÚ´õ
Ç¥ÁØÀúÇ×ÃøÁ¤
BATTERY ÃøÁ¤±â
¸ðÅÍȸ·ÎºÐ¼®±â
°¡¿¬¼º°¡½ºÃøÁ¤±â
³Ã¸Å°¡½ºÃøÁ¤±â
º¹ÇÕ°¡½ºÃøÁ¤±â
´ÜÀϰ¡½ºÃøÁ¤±â
ÃÊÀ½ÆÄ´©¼³Å½Áö±â
VOCÃøÁ¤±â
¿¬¼Ò°¡½ºÃøÁ¤±â
Á¡µµ°è
À¶Á¡ÃøÁ¤±â
ÇöÀçÀ§Ä¡ : Home > °æµµ ½ÃÇè±â > ·ÎÅ©À£°æµµ°è > HIGHWOOD(·ÎÅ©À£) > ·ÎÅ©À£ °æµµ°è HWDR-1 /HWDR-3
·ÎÅ©À£ °æµµ°è HWDR-1 /HWDR-3
»óǰ°¡°Ý : °¡°Ý¹®ÀÇ
Á¦Á¶¿ø : HIGHWOOD
±¸¸Å¼ö·® : °³
°áÁ¦±Ý¾× : °¡°Ý¹®ÀÇ

+ »óǰ¼³¸í
¡Ý Æ¯Â¡ (Features)

   -   Á¢Ã˽Ġ¾×Á¤ È­¸é : »ç¿ëÇ챉ʮíÇÑ Á¢Ã˽Ġ¾×Á¤ È­¸é »ç¿ëÇÏ¿© »ç¿ëÀÌ ¿ëÀÌ

   -   ÀÚµ¿ µ¿ÀÛ : ÇÏÁß ¼³Á¤ ÈÄ ÀÚµ¿ ½ÃÇè°¡´É

   -   ½¬¿î Á¶ÀÛ : ¹à°í ¸¼Àº È­¸éÀ¸·Î º¼ ¼ö ÀÖÀ¸¸ç ¼Ò¸®·Îµµ ÁøÇà »çÇ×À» ¾Ë ¼ö ÀÖ´Ù.

   -   Æ°Æ°ÇÑ ±¸Á¶ : »õ·Î¿î µðÀÚÀÎÀ¸·Î °í Á¤¹Ð½ÃÇèÀÌ °¡´ÉÇÏ´Ù.

   -   ´Ù¾çÇÑ ÀÚ·á Á¤¸® ±â´É : 256°³ÀÇ ÀÚ·á ÀúÀå ¹× ´Ù¸¥ ½ºÄÉÀÏ·ÎÀÇ °á°úÄ¡ º¯È¯, Åë°è µî ±â´É ºÎ¿©

   -   ´ÙÀ̾ó Å¸ÀÔÀ¸·Î º¯È¯ ¿ëÀÌ : ´ÙÀ̾ó Å¸ÀÔÀÇ º¯È¯ÀÌ ¿ëÀÌÇÏ¿© ÀÀ±Þ½Ã º¯È¯ ¿ëÀÌ

   -   ¾ÈÀüÇÑ ±¸Á¶ : °úºÎÇÏ ¹× ÁöÁøµî¿¡µµ Ãʰú ÇÏÁßÀÌ °É¸®Áö ¾ÊÀº ¼³°è

¡Ý Specifications(±â¼ú»ç¾ç)

 

ITEM

CONTENS

Minor load

HWDR-1

 98.07 N     10 Kgf

HWDR-3

 29.42 N     98.07 N       3.01 Kgf

Test load

HWDR-1

                                     588.4      980.7     1471     N

                                         60        100       150      Kgf

HWDR-3

 147.1     294.2     441.3     588.4     980.7     1471     N

     15        30          45         60        100        150    Kgf

Minor load position setting

 Automatic setting (LCD graph & electronic signal monitoring fine is unnecessary

Load control

 Automatic (Loading  - holding  - release)

Start operation

 Automatic  start / Manual start selection

Dwell Time

 1 -99 sec (key entry in units of seconds)

Plastic measurement

 Standard function, time up to hardness value display after release : 1 to 99 sec

Scale display

HWDR-1

 C, D, A, G, B, F. K, E, H, P, M, L, V, S, R

HWDR-3

 15 N, 30 N, 45 N, 15 T, 30 T, 45 T, 15 W, 30 W, 45 W, 15 X, 30 X, 45 X

 15Y, 30 Y, 45 Y, C, D, A, G, B, F, K, E, H, P, M, L, V, S, R

Data output

 1) Centronics (standard)

 2) RS232C or serial output selectable (Factory setting : RS232C)

Dta memory

 Max. 256 test data

 Hardness converstion

 Specified scale on real time display

 OK / NG criteria

 Upper and lower limits setting, and HI/OK/LOW display

 Data edition

Batch converstion of memorized measurment data(Meanvalue, max.value, min.value  standard deviation, dispersion (R)). Converted values, same too.

RS-232C Communication line

 Baud rete : 1200/2400/4800/9600 bps selectable(RS232C)

 Error detection, Parity even / Parity none / selectable (RS232C)

 Accuracy

 Conform to JIS B7726 and ASTM-18

 Max. speciemen height

HWDR-1

 250 mm

HWDR-3

 200 mm

 Max. Specimen depth

 160 mm

 Dimensions & Weight

W220 x D550 xH830 , 80 Kg

 Power supply

 Single phase AC 100 - 240V 50/60 Hz available for export model

 subject to chan without prior notic specification :

 

¡Ý Standard Accessories

ITEM

HWDR-1

HWDR-3

Hardness standard block

HRC60

1

1

HRB90

1

1

80HR30N

-

1

75HR30T

-

1

Diamond indenter(Buily in)

1

1

Steel ball indenter(1/16")

1

1

Spare stell ball(1/16")

10

10

Anvil

60mm flat

1

1

V-shape

1

1

Lighting device(LED : green)

Option

Option

Spare fuse 100-120V 3A, 200-240V 2A

2

2

Power cord(3P - 2.5m)

1

1

Level adjusting leg

4

4

Auxiliary tools

1

1

Attachment for prevent the machine fall

1

1

Machine cover

1

1

 

¡Ý Optional Accessories
 

Item

Contents

Steel ball indenter

1/8", 1/4". 1/2" and 3/4" dia.

Steel ball

1/8", 1/4", 1/2" and 3/4" dia.

Roud table

200mm dia. (Not tempered)

Anvil

V-shape (small), Spot, Daimeond spot

Long specimen

testing jig

Vari  - rest

Jack - rest

Micro test table

for jominy test

Max. movement : approx, 55mm

Min. micro graduation : 1/10 mm or 1/160"

Printer iDP-3110

Form Hardness tester add up to result to data output






 

ȸ»ç¼Ò°³   |   ÀÌ¿ë¾È³»   |   ÀÌ¿ë¾à°ü   |   °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§   |   Help Desk   |   Site Map  

 

  

 

»óÈ£ : (ÁÖ)¹ß¸¸ÀνºÆ®·ç¸ÕÆ®  ´ëÇ¥ : ÀÓµµ¼ö  

»ç¾÷ÀÚ¹øÈ£ : 610-81-5248   Åë½ÅÆÇ¸Å¾÷½Å°í¹øÈ£ : Á¦2018-¿ï»êÁß±¸-0128È£ 

ÁÖ¼Ò : ¿ï»ê±¤¿ª½Ã Áß±¸ ÇÔ¿ù12±æ 53  

ÀüÈ­ : 052-257-9430  ÆÑ½º : 052-257-9470 

E-Mail : gbs2564@balmann.com